Do you have a Growatt Solar Inverter Error 117 Issue?
An error we have seen many times with Growatt solar inverters is the “Error 117” message.
When a Growatt inverter displays the “Error 117” message the red Fault light will be lit and the inverter will not be producing any power; the inverter is telling you that it has detected a problem with the internal relay inside the inverter and due to this fault it cannot function. You want to do something about this ASAP as when the Error 117 code is displayed you will not be receiving any benefit at all from your solar power system.
Please be aware the system is safe, it just will not produce any power while the Error 117 code is being displayed.
What can you do about a Growatt Solar Inverter Error 117 issue?
If the inverter is coming up with this fault it will need replacing. You may be able to get it working temporarily by rebooting the inverter by following the shutdown procedure as shown below.
- Turn off the SOLAR SUPPLY MAIN SWITCH or Inverter AC Isolator (if installed).
- Turn off the PV Array DC Isolator located at the inverter.
- Wait for approximately 1 minute.
- Turn on the SOLAR SUPPLY MAIN SWITCH or AC Isolator (if installed).
- Turn on the PV ARRAY DC Isolator.
- Wait a few minutes for the inverter to restart.
- Check to see if the error has cleared.
If the inverter is still within the 5-year warranty period Growatt will cover an Error 117 under warranty – however be aware that Growatt do not cover the cost of a solar accredited technician visiting your property to remove and replace the faulty inverter so there will be a cost involved in having your Growatt inverter repaired under warranty.
To make a warranty claim you will need to provide proof of purchase in the from of a tax invoice or Certificate of Compliance from when it was originally installed along with the model and serial numbers found on the side of the inverter.
If you don’t want to deal with Growatt’s warranty terms or the inverter is outside the 5 year warranty period then the best thing to do is to have the inverter replaced with a good quality replacement model with a full factory warranty that will serve you well for many years to come.
If you need further help with your Growatt Solar Inverter Error 117 issue please complete the form above under the URGENT heading and we’ll assist you further.
Need more information on Growatt solar inverters? Checkout the below.
For more information on Growatt solar inverters including inverter datasheets, manuals, fault codes etc. click here.
Click here to get your solar power system back saving you money rather than costing you money!
Got A Question About Solar Power? Click Here For Answers!
Hi. My Growatt 5000SPF is about 18 months old and i do have a 117 error on it. When error 117 occur the unit stop working. I bought it from an agent and found one Growatt at the agent waiting to be send back to China for repairs. How long will that take and what do i do in the meantime. I do not have any earthing problems. My unit and the rest of equipment are properly earthed.
Can i take it to an electronic repair shop and asked the guy to replace the relay. Can we use a better type of relay because to me it sounds like a common problem with Growatt.
I am not impressed by this fault
Hi, the Growatt inverter error 117 relay issue is not usually caused by an earthing problem but it may be made worse if an earthing problem is present.
Hello sir, this relay issue will occur due to ac earthing problem,
Hi Kamlesh, thanks for your enquiry, the relay is soldered onto the circuit board inside the inverter and isn’t a part which is normally replaced. The recommended course of action is to either replace the inverter or send the inverter to a repair shop specialising in electronics to have this issue rectified.
How to replace relay