If you have CMS 2000 or CMS 1500 solar inverter that is displaying an error message or a red light check out the table below to find out what the message means. Unfortunately the manufacturer of these inverters are not honouring any warranties, so an error message may possibly mean you are up for some money to get your solar power system operational again. Click here for more information.
CMS 1500 and CMS 2000 Fault and Error Messages
Operating Message |
Message in English |
Description |
System Fault & Error Messages |
||
Isolation fault | Isolation failure | Earth fault on the solar panels or failure of surge protection |
Ground I Fault | GFCI active | Leakage current to ground is too high |
Grid fault | Grid failure | Grid measured data is beyond the specification (voltage & frequency) |
No utility | No utility | Utility is not available |
PV over voltage | Input voltage too high | Input voltage from the solar panels higher than the max input voltage |
Inverter Fault and Error Messages |
||
Consistent fault | Consistent failure | The readings of 2 microprocessors are not consistent. CPU and/or other circuit not functioning may be the cause. |
Over temperature | Temperature too high | The internal temperature is higher than the normal value |
Relay failure | Output relay failure | The relay between the inverter and grid is not functional |
DC INJ High | Output DC injection too high | Output DC injection is too high |
EEPROM failure | EEPROM problem | EEPROM inside the inverter has a data access problem |
SCI failure | Problem with communication between microprocessors | The communication between MCU inside the inverer is abnormal |
High DC Bus | DC bus voltage is too high | The DC Bus inside is higher than expected |
Low DC Bus | DC bus voltage is too low | The DC bus inside is lower than expected |
Ref 2.5V Fault | 2.5V reference voltage inside problem | The 2.5V reference inside the inverter is abnormal |
DC Sensor Fault | Output DC sensor abnormal | The DC output sensor is abnormal |