Solis inverter problems
Ginlong Solis Solar Inverter is a value-priced brand of inverters manufactured in China. Due to the high range of faults that Chinese inverters are known for there are not a lot of reputable solar installing companies that offer this inverter.
But if you find that there’s a fault in your Ginlong Solis Solar Inverter, we have put together a list of faults, descriptions, and actions from the Ginlong Solis user manual for your quick reference.
For this inverter, the LCD screen will display an alarm message in case of failure. When this happens the inverter may stop feeding into the grid. Here are the failure descriptions and their corresponding alarm messages.
Alarm Message | Failure description | Proper Shutdown Procedure |
OV-G-V | Over grid voltage | If the inverter displays any alarm message on this list, turn off the inverter and wait for 5 minutes before restarting it. Refer to the instructions below to stop and start your inverter. If the failure persists, please contact your local distributor or the service center.
To stop the Inverter, the following steps must be strictly followed: 1. Switch the Grid Supply Main Switch (AC) OFF. 2. Wait 30 seconds. Switch the DC Isolator OFF. All the LEDs of the inverter will be off in a minute. To start up the Inverter, it is important that the following steps are strictly followed: 1. Switch the Solar Supply Main Switch (AC) ON first. 2. Switch the DC Isolator ON. If the voltage of PV arrays is higher than start up voltage, the inverter will turn on. The red LED power will light, and the LCD shows the company’s name and the inverter model. 3. When both the DC and the AC grid sides supply to the inverter, it will be ready to generate power. Initially, the inverter will check both its internal parameters and the parameters of the AC grid, to ensure that they are within the acceptable limits. At the same time, the green LED will flash and the LCD displays the information of INITIALIZING. 4. After 30-180 seconds (depending on local requirement), the inverter will start to generate power. The green LED will be on continually and the LCD displays GENERATING. |
UN-G-V | Under grid voltage | |
OV-G-F | Over grid frequency | |
UN-G-F | Under grid frequency | |
G-IMP | High grid impedance | |
NO-GRID | No grid voltage | |
OV-DC | Over DC voltage | |
OV-BUS | Over DC bus voltage | |
UN-BUS | Under DC bus voltage | |
GRID-INTF. | Grid interference | |
INI-FAULT | Initialization system fault | |
OV-TEM | Over Temperature | |
GROUND-FAULT | Ground fault | |
ILeak-FAULT | High Grid leakage current | |
Relay-FAULT | Relay check fault | |
DCinj-FAULT | High DC injection current |
The full information is available in the Ginlong Solis solar inverter manual’s troubleshooting section. In case performing the steps above does not fix the issue and your Ginlong Solis Solar Inverter is still within the warranty period you can contact the equipment installer or supplier. Be ready with the serial number, installation date, description of the issue and system design for the PV array configuration (e.g. number of panels, capacity of panels, number of strings, etc.).
If your inverter is outside the warranty period we suggest that you contact a professional solar power expert. If you’re in the Gold Coast or Brisbane area contact Gold Coast Power Solutions here and we will be in touch to provide you with further assistance.
Got A Question About Solar Power? Click Here For Answers!
I get the error code limbyepm
What dose this mean
Hi Mathew,
An Over Voltage error can be a few things.
You can try to run a few of the more energy demanding appliances in your house (washing machine, A/C etc) to see if that error goes away. The OV error can be caused when there is more power produced by the inverter than is being used or can be fed back to the grid. running more appliances (more load) can help here. doing this will not “fix” anything, only help diagnose why the error is coming up.
Also, if the mains grid voltage is to high then the inverter can detect this and give the OV error. you need to do the above test first and if the OV error persists, contact you energy provider to see what the line voltage is in your area at that time.
Hi my solar system most of the time says LimByVg has said this since new called the call center as come up with a fault over voltage so got into the main settings and raised it but is still in LimByVg most of the time what is the recommendation now it’s not even a year old really sick of it already
Hi Jimmy, the LimByVg message on your Solis inverter will mean that the voltage on the grid is getting higher than the Solis inverter is set to allow. This is not a fault with the inverter, it’s just the voltage is going outside of its parameters. It may be worth talking to your solar power system installer to see if anything can be done to improve this.
Hi i have solis inverter recently i noticed when i get to 3.4 kw above i will get LimByVg (limit by voltage) status showing up, are the electric company try to limited what im selling to them? Or what is mean?